2.1.2 RS-485 (Modbus RTU)

RS 232 pinning — 2.1.2 RS-485 (Modbus RTU)

Port pinning

PinFunctionPigtail wire color
1GNDbrown
2Bred
3Aorange
4VIN, 5V or 3.3Vblack

RS-485 (Modbus RTU)

SmartSampler2 uses this half-duplex RS-485 interface for compatible Modbus RTU instruments. The baud rate, serial frame, device address, register definitions, byte order, scaling, and offset must match the connected device.

Related configuration: 4.2.5 RS-485 (Modbus RTU) in SmartConfig2.