SmartSampler2 firmware

SmartSampler2 firmware downloads and complete release history.

Firmware SmartSampler

Download the latest firmware for the SmartSampler here. If you require support for an older firmware version, please contact us.

SmartSampler2

V0.3.8 (21.08.2026)

  • Improved SDI12/Modbus handling
Changelog

V0.3.7 (19.08.2026)

  • Improved SDI12 handling

V0.3.6 (13.08.2026)

  • Improved Wireless connection
    • Enforced default connection

V0.3.5 (11.08.2026) only compatible with SmartConfig2 V0.2.7 and above

  • Improved Wireless connection
    • real time update
    • enhanced security

V0.3.4 (08.08.2026)

  • Improved wireless conection

V0.3.3 (28.07.2026)

  • Improved Serial Handling

V0.3.2 (26.07.2026)

  • Improved Serial Handling and Debug report

V0.3.1 (23.07.2026)

  • New Feature: High Resolution data upload

V0.3.0 (22.07.2026)

  • Bugfix: Imports now also Sensor port configuration

V0.2.9 (21.07.2026)

  • New Feature: Export/Import settings, included telemetry configuration
  • Improved telemetry connectivity

V0.2.8 (20.07.2026)

  • New Feature: Export/Import settings, configurations and program to a new system

V0.2.7 (2026_07_10)

  • Added: temporary counters in user defined mode data/telemetry output

V0.2.6 (2026_07_03)

  • Bugfix: Fixed real-time clock synchronization

V0.2.5 (2026_07_02)

  • Improved cellular communication reliability
  • Faster cellular network initialization
  • Enhanced MQTT live communication
  • Increased user-defined variables to 12
  • Increased formula capacity to 20
  • Various performance and stability improvements

V0.2.4 (2026_06_20)

  • Improved deep sleep reliability
  • Added reduced payload mode to lower data usage.
  • Added local time handling while keeping correct UTC timestamps for telemetry.
  • Improved support for longer cellular/telemetry messages.
  • Added Smart Sampler Solutions telemetry platform.

V0.2.3 (2026_05_27)

  • added discarding sensor read in User defined mode
  • added guard ensuring to stay in allowed range of user defined program

V0.2.2 (2026_05_11)

  • Bugfix:
    • Modbus header and value fix via telemetry
    • SDI-12 variable fix via telemetry

V0.2.1(2026_04_19)

  • Improved sensor stability to prevent crashes from unexpected behavior
    • applies to Modbus and SDI-12
  • Updated TreeFlux mode for revised setup compatibility
  • Removed unnecessary spaces in file header
  • Improved storage reliability
  • Telemetry updates:
    • Initial GPS support added
    • GPS and LTE cannot be used at the same time

V0.2.0 (2026_03_04)

  • Fixed RS-485/Modbus sensor data request

V0.1.9 (2026_02_27)

  • User defined mode
    • increased temp storage in user defined program from 3 to 6
    • improved internal user def program checker
    • Parameter O used in temp storage and counter funktions for define number
    • Parameter S used in temp storage and counter funktions for setting/comparing
  • minor fixes for cellular

V0.1.8 (2026_02_19)

  • Modbus
    • added optional trigger for measurement before data request

V0.1.7 (2026_02_07)

  • Improved: stricter validation of user-defined programs — firmware now detects and reports code issues before continuing.

V0.1.6 (2026_02_04)

  • RS-485: Function code 04 added for sensor request

V0.1.5 (2026_02_01)

  • Bugfix in Pulse counter

V0.1.4 (2026_01_29)

  • User defined parameter place holder changed to A,B,C,D,E,G
    • A,B,C,D,E,G can be used as place holder in user defined code
  • addapting code to new hardware

V0.1.3 (2026_01_22)

  • first release to match SmartSampler2 hardware
  • added Auto Start feature

V0.1.2 (2026_01_10)

  • bug fixes on transmitter communication

V0.1.1 (2025_12_11)

  • Added 6 user defineable Parameter/Placerholder for the Programm code
  • Improved PulseCount accuracy
  • Added RelayModule

V0.1.0 (2026_11_14)

  • Update FlowControl use (continoue saving data during use)

V0.0.9

  • set to work 3 TreeFlux modules at once
  • bugfix module power up

V0.0.8

  • Cleaned Sampler Modes
  • Added Uart 3 option
  • Release of TreeFlux sampler mode

V0.0.7

  • Serial channels can now change between settings
  • imrpoved modbus handling (Software SmartConfig2 V0.0.7 needed)

V0.0.6

  • Bug fix FlowControl
    • unable to calibrate values above 255 (units)
  • Added 1 second reading from FlowControl after pump has been switched off

V0.0.5

  • Small bug fixes related to the FlowControl
  • While FlowControl is in use no other sensor readings will be updated

V0.0.5

  • Modbus RTU/RS-485 integration
  • Read all sensors while in UserDef FlowCotntrol function
  • Bugfix:
    • display code lines in data log from 1 not 0
    • LED blinks every second if running, always on if in USB mode

V0.0.4

  • Slightly more accurate SDI-12 timing

V0.0.3

  • Added Pods
  • improved communication to SmartConfig
    • SmartConfig2 V0.0.4 needed
  • added formula support
  • Enabled time update via telemetry

V0.0.0 – 0.0.2

  • beta test release