Downloads & release history
SmartSampler2 firmware
SmartSampler2 firmware downloads and complete release history.
SmartSampler firmware
Download the latest firmware for the SmartSampler here. If you require support for an older firmware version, please contact us.
SmartSampler2
V1.0.2 (21.11.2026)
More resilient logging and device-health reporting
- More resilient data logging Added write verification, automatic SD-card recovery and temporary measurement buffering during storage interruptions. Buffered measurements retain their original timestamps.
- Device-health reporting Added storage status, pending measurements, recovery counts and the last successful save time for monitoring over USB and telemetry.
- Clearer diagnostics Regular updates provide visibility into supply voltages, storage health and the current telemetry connection stage.
- Improved remote updates on SmartSampler2 A dedicated update sequence coordinates sampling, storage and restart. Pending measurements must be saved before the update proceeds.
- Improved remote communication Refined command-response handling and secure connection recovery on SmartSampler2.
Temporary measurement buffering holds up to 32 records or 8 KB, whichever limit is reached first. Buffered records remain in memory until saved and are lost if the controller restarts.
Full change log
V1.0.1 (11.11.2026)
More TreeFlux control and automatic telemetry recovery
- More control over TreeFlux preparation Set tubing pre-flush, zero-air filling and bag evacuation times independently. Choose how many times to repeat preparation, and set the chamber flush time to zero to skip that step.
- Clearer feedback in the field Follow preparation progress and updated sensor readings during TreeFlux operation. A brief LED flash shows when the sampler is awake and waiting.
- Automatic telemetry retries SmartSampler2 retries cellular and telemetry connections after an interruption while keeping the sampling schedule on track. Cellular telemetry uses LTE-M.
- Regular clock checks The sampler checks its clock after connecting to LTE and every six hours while connected.
Before operating TreeFlux after the upgrade, use SmartConfig2 0.3.4 to review and save the preparation settings. The former bag flush setting now sets the evacuation time.
V1.0.0 (29.10.2026)
- Separate firmware builds support SmartSampler1 and SmartSampler2.
- Standardized timekeeping across both controllers: the internal clock uses UTC, while displayed and SD-card timestamps show local time with the corresponding ISO 8601 offset.
- Improved LTE clock parsing and offset handling, including offsets expressed in minutes.
- Added validation to reject RTC, USB, and LTE times earlier than the firmware build date. An invalid RTC is initialized to the build date until a valid current time is set.
- Updated USB clock setting to also set the RTC, preserving the new time across sleep and wake cycles.
- Improved telemetry and remote command handling on SmartSampler1.
- Sampler information is available when cellular telemetry connects and refreshes approximately every 12 hours.
Compatibility and upgrade notes
Use the firmware build for the selected controller. SmartSampler2 retains its supported sampling modes and over-the-air updating. SmartSampler1 supports User-defined mode and external telemetry; over-the-air updating is not available for SmartSampler1.
SmartSampler1 upgrade action required: On the first boot with unified firmware, operating settings reset to defaults and automatic start is disabled. The ten factory calibration values, product identity, and license metadata are preserved. Back up the existing settings before upgrading, then review and re-enter the program, sensors, outputs, logging, telemetry, and time zone. Verify calibration, readings, timestamps, and remote commands before re-enabling automatic start.
If an invalid RTC has fallen back to the build date, set the current time over USB or obtain a valid LTE clock update before relying on timestamps.
Validation status: Both hardware targets compile. Hardware validation of sampling, calibration, timestamps, telemetry, and supported update behavior is still required before customer deployment.
V0.4.0 (29.09.2026)
- Added a reset action for connected modules in User-defined programs.
- Changed telemetry and SD-card timestamps to ISO 8601 format.
- Updated manual time-offset handling when LTE time updates are enabled.
- Improved wireless communication under network latency and restricted cellular registration to compatible Cat M1 networks and providers.
V0.3.9 (23.08.2026)
- Improved handling of short final blocks during firmware downloads.
- Removed Send while idle and improved topic-based telemetry transmission.
V0.3.8 (21.08.2026)
- Improved SDI-12 and Modbus handling.
V0.3.7 (19.08.2026)
- Improved SDI-12 sensor communication.
V0.3.6 (13.08.2026)
- Improved Wireless connection
- Enforced default connection
V0.3.5 (11.08.2026) only compatible with SmartConfig2 V0.2.7 and above
- Improved Wireless connection
- real time update
- enhanced security
V0.3.4 (08.08.2026)
- Improved wireless connectivity.
V0.3.3 (28.07.2026)
- Improved Serial Handling
V0.3.2 (26.07.2026)
- Improved Serial Handling and Debug report
V0.3.1 (23.07.2026)
- Added high-resolution data upload.
V0.3.0 (22.07.2026)
- Settings imports now include sensor port configuration.
V0.2.9 (21.07.2026)
- Export and import settings with telemetry configuration included.
- Improved telemetry connectivity
V0.2.8 (20.07.2026)
- Transfer settings, configuration and programs to a new system with export and import.
V0.2.7 (2026_07_10)
- Added: temporary counters in user defined mode data/telemetry output
V0.2.6 (2026_07_03)
- Improved real-time clock synchronization.
V0.2.5 (2026_07_02)
- Improved cellular communication reliability
- Faster cellular network initialization
- Enhanced MQTT live communication
- Increased user-defined variables to 12
- Increased formula capacity to 20
- Various performance and stability improvements
V0.2.4 (2026_06_20)
- Improved deep sleep reliability
- Added reduced payload mode to lower data usage.
- Added local time handling while keeping correct UTC timestamps for telemetry.
- Improved support for longer cellular/telemetry messages.
- Added Smart Sampler Solutions telemetry platform.
V0.2.3 (2026_05_27)
- added discarding sensor read in User defined mode
- added guard ensuring to stay in allowed range of user defined program
V0.2.2 (2026_05_11)
- Improved Modbus headers and values and SDI-12 variable reporting over telemetry.
V0.2.1(2026_04_19)
- Improved sensor stability to prevent crashes from unexpected behavior
- applies to Modbus and SDI-12
- Updated TreeFlux mode for revised setup compatibility
- Removed unnecessary spaces in file header
- Improved storage reliability
- Telemetry updates:
- Initial GPS support added
- GPS and LTE cannot be used at the same time
V0.2.0 (2026_03_04)
- Improved RS-485/Modbus sensor data requests.
V0.1.9 (2026_02_27)
- User defined mode
- increased temp storage in user defined program from 3 to 6
- improved internal user def program checker
- Parameter O used in temp storage and counter funktions for define number
- Parameter S used in temp storage and counter funktions for setting/comparing
- Refined cellular communication.
V0.1.8 (2026_02_19)
- Modbus
- added optional trigger for measurement before data request
V0.1.7 (2026_02_07)
- Improved: stricter validation of user-defined programs — firmware now detects and reports code issues before continuing.
V0.1.6 (2026_02_04)
- RS-485: Function code 04 added for sensor request
V0.1.5 (2026_02_01)
- Improved pulse counter operation.
V0.1.4 (2026_01_29)
- User defined parameter place holder changed to A,B,C,D,E,G
- A,B,C,D,E,G can be used as place holder in user defined code
- addapting code to new hardware
V0.1.3 (2026_01_22)
- first release to match SmartSampler2 hardware
- added Auto Start feature
V0.1.2 (2026_01_10)
- Improved communication with the transmitter.
V0.1.1 (2025_12_11)
- Added 6 user defineable Parameter/Placerholder for the Programm code
- Improved PulseCount accuracy
- Added RelayModule
V0.1.0 (2026_11_14)
- Update FlowControl use (continoue saving data during use)
V0.0.9
- set to work 3 TreeFlux modules at once
- Improved module power-up handling.
V0.0.8
- Cleaned Sampler Modes
- Added Uart 3 option
- Release of TreeFlux sampler mode
V0.0.7
- Serial channels can now change between settings
- imrpoved modbus handling (Software SmartConfig2 V0.0.7 needed)
V0.0.6
- FlowControl calibration supports values above 255 units.
- Added 1 second reading from FlowControl after pump has been switched off
V0.0.5
- While FlowControl is in use no other sensor readings will be updated
V0.0.5
- Modbus RTU/RS-485 integration
- Read all sensors while in UserDef FlowCotntrol function
- Program line numbers in the data log start at 1.
- The status LED flashes every second during operation and stays lit in USB mode.
V0.0.4
- Slightly more accurate SDI-12 timing
V0.0.3
- Added Pods
- improved communication to SmartConfig
- SmartConfig2 V0.0.4 needed
- added formula support
- Enabled time update via telemetry
V0.0.0 – 0.0.2
- beta test release