Modular field instruments · Engineered and produced in Germanyinfo@smartsamplersolutions.com

3. Installation

3. Installation

  1. Disconnect SmartSampler2 and the field power supply.
  2. Mount the PowerExpander securely with enough clearance for connectors and cables.
  3. Connect the module to the designated compatible SmartSampler2 expansion interface.
  4. Connect each field load to its assigned output port.
  5. Fit a fuse selected for the load and cable. Do not exceed 7.5 A per port.
  6. Tighten all weatherproof connectors and close unused ports with their protective caps.
  7. Restore power and confirm that the PowerExpander is available in SmartConfig2.
  8. Test each output individually before starting unattended operation.

Important: If a fuse opens during commissioning, find and correct the overload, short circuit, wiring fault, or stalled load before replacing it.

Ask an engineering questionSoftware & downloads