Firmware SmartSampler

[featured_image]
Download
Download is available until [expire_date]
  • Version V1.1.5
  • Download 22
  • File Size 267 KB
  • File Count 1
  • Create Date August 3, 2022
  • Last Updated December 9, 2024

Firmware SmartSampler

Latest firmware version for the SmartSampler

V1.1.5

  • bugfix: possible fix with communication error between SmartTransmitt and Sampler
  • increased time for connecting with server

V1.1.4

  • bugfix: timeoffset can be send through SmartConfig2.0

V1.1.3

  • bugfix: applied time offest did gets lost after repower

V1.1.2

  • added info if switch carrier operator
  • added feeback messages from cellular for default operation
  • do not update time from cellular if time is off for more then a year

V1.1.1

  • added roaming SIM option

V1.1.0

  • added cellular infos during powerup
  • Added reset function
  • added ability to request settings via MQTT
  • added option to delete certificates

V1.0.9

  • added more debug informations for transmitter
  • set timeout for choosing different provider to 3 minutes

V1.0.8

  • some bug fixes

V1.0.6

  • added HTTP and MQTT functions
  • firmware log added

V1.0.5

  • improved firmware download with debug informations

V1.0.4

  • some bug fixes

V1.0.3

  • send only data if variable and value has content

V1.0.2

  • Enable registration to home network

V1.0.1

  • Added debug informations

V1.0.0

  • Updated firmware to access the transmitter directly
    • will update transmitter firmware over the air
  • Enhanced firmware update server
  • real time 2-way communication
  • improved connectifity to server

V0.2.5

  • store historic data if transmitter is in use but not online for later upload
  • added user defined functions

V0.2.4

  • bugfix
    • Lost calibration point on Analog1-1 High value
    • fixed analog read offset

V0.2.3

  • improved user license system
    • update license for already sold systems
  • automatic update to default settings for wrong configured system

V0.2.2

  • added eagle dashboard support (SmartTransmit firmware 0.1.1 and upward)
  • introduced user license
  • added SDI-12 support

V0.2.1

  • bugfix EXO singel data request and wipe command

V0.2.0

  • added output 4 support

V0.1.9

  • added "gravity drained" option to use all outputs for pumping

V0.1.8

  • faster update of values
  • fixed RS232 variable naming

V0.1.7

  • added posibility to use differnt sd file save speeds for larger data files

V0.1.6

  • start sampler automaticly after 10 minutes without receiving a command

V0.1.5

  • reduced save speed of datalog file in order to safely store file to selected location

V0.1.4

  • added SDI-12 to RS-232 Adapter support
    • valid SDI addresses from 0 to 9
  • added daily reset option
    • reset the sampler every 24h after it started
  • improved GPS update
  • Multiplexer can now also be controlled by PWM

V0.1.3

  • added Power Save mode if voltage drops below threshold
    • decreases pump time by 2
    • increases interval time by 2

V0.1.2

  • can now communicate also with SmartTransmit firmwaer V0.0.8 and below
  • SmartConfig Version 1.1.1 and above needed to setup connected modules

V0.1.1

  • Fixed communication issue with EXO 2/RS-232
  • Firmware compatible with SmartTransmit firmware 0.0.9 and above

V0.1.0 beta

  • Fixed communication issue with old SmartTransmit firmware (below 0.0.9)
  • Fixed communication issue with EXO 2/RS-232

V0.1.0

  • minor improvements

V0.0.9

  • changed warm up time from seconds into minutes
  • added ability to update SmartTransmit firmware via network
    • 10 minutes timeout for updating firmware
  • added power save mode
    • switch off connected devices if supply voltage drops below threshold
  • added EXO support
  • changed power save settings
    • will save power for each ticked option

V0.0.7

  • use the warm up time also for all sensors
  • read all the sensors for set time to eliminate false readings in datalog

V0.0.6

  • fixed problem with Leadmed Multiprobe
    • buffer was used the wrong way, did count each time we shiffeted data into the buffer
  • print now back the incoming data from Leadmed Multiprobe without buffering

V0.0.5

  • added warm up time before the actual sample process
    • enables the transmitter to connect to the server
    • restart transmitter during sampling as often as it takes to establish connection
    • improved connection time

V0.0.4

  • Improved analog reading accuracy
  • switch on RS-485 power supply if a RS-485 device has been selected

V0.0.3 beta

  • bug fix module communication

V0.0.3

  • added basic debug information from transmitter
  • updated the data handling for the latest Leadmed multi sensor
  • bug fix
    • data download issue

V0.0.2:

  • added functions
    • Up to 18 power ports can now be switched
    • increase communication speed between SmartSampler and SmartTransmit
      • transmitter must have at least firmware V0.0.1
    • LED will now also blink for debug purposes

V0.0.1:

  • Minor bug fixes
    • fixed restart on high data update rates
  • added functions
    • added basic information stream to transmitter
    • fine tuning of the power outputs now possible
    • updates settings over transmitter

V0.0.0:

  • Initial upload.

Old versions